             Downlink (TX) Path 
             | 
            
             700 
             | 
            
             900 
             | 
        
| 
             Frequency Band 
             | 
            
             778 -803 
             | 
            
             940 - 950 MHz 
             | 
        
| 
             Insertion Loss 
             | 
            
             0.5 dB 
             | 
            
             0.5 dB 
             | 
        
| 
             Return Loss 
             | 
            
             ≥ 18 dB 
             | 
            
             ≥ 18 dB 
             | 
        
| 
             Average input power 
             | 
            
             ≥ 150 W 
             | 
            
             ≥ 150 W 
             | 
        
| 
             Peak input power 
             | 
            
             ≥ 1.6 KW 
             | 
            
             ≥ 1.6 KW 
             | 
        
| 
             Intermodulation, 2x43 dBm TX Carrier BTS port 
             | 
            
             -117 dBm in RX band, ANT port 
             | 
            
             -117 dBm in RX band, ANT port 
             | 
        
| 
             Uplink (RX) Path 
             | 
        ||
| 
             Frequency Band 
             | 
            
             723 - 748 
             | 
            
             890 -905 MHz 
             | 
        
| 
             Gain 
             | 
            
             12 dB nominal 
             | 
            
             12 dB nominal 
             | 
        
| 
             Ripple(dB) 
             | 
            
             ≤ 2 
             | 
            
             ≤ 2 
             | 
        
| 
             Return Loss 
             | 
            
             ≥ 18 dB 
             | 
            
             ≥ 18 dB 
             | 
        
| 
             Noise Figure 
             | 
            
             2 dB 
             | 
            
             2 dB 
             | 
        
| 
             Insertion Loss, Bypass mode 
             | 
            
             2 dB 
             | 
            
             2 dB 
             | 
        
| 
             Return Loss, Bypass mode 
             | 
            
             ≥ 18 dB 
             | 
            
             ≥ 18 dB 
             | 
        
| 
             Output IP3 
             | 
            
             >24 dBm 
             | 
            
             >24 dBm 
             | 
        
| 
             Power Supply and Alarm 
             | 
            
             | 
            
             AISG - Mode 
             | 
        
| 
             DC 
             | 
            
             | 
            
             24 V DC nominal (9-30 V DC) 
             | 
        
| 
             Power 
             | 
            
             | 
            
             < 4 W 
             | 
        
| 
             Alarm 
             | 
            
             | 
            
             3GPP/AISG 2.0 
             | 
        
| 
             Environmental 
             | 
        ||
| 
             Operating Temperature Range 
             | 
            
             -40 to +65°C | -40 to +149°F 
             | 
        |
| 
             Operation 
             | 
            
             ETS 300 019-1-4 Class 4.1E 
             | 
        |
| 
             Storage 
             | 
            
             ETS 300 019-1-1 Class 1.2 
             | 
        |
| 
             Ingress Protection 
             | 
            
             IP67 
             | 
            
             | 
        
| 
             Lightning Protection 
             | 
            
             5 kA 8/20 µs (ANT, BTS) 
             | 
        |
| 
             3 kA (RET port) 
             | 
            
             | 
        |
| 
             Miscellaneous 
             | 
        ||
| 
             EMC 
             | 
            
             EN 301 489-50 
             | 
            
             | 
        
| 
             Safety standards 
             | 
            
             IEC/EN 62368-1 
             | 
            
             | 
        
| 
             MTBF 
             | 
            
             1 Mh/TMA min. 
             | 
            
             | 
        
| 
             Mechanical 
             | 
        ||
| 
             Dimensions (WxHxD) 
             | 
            
             245x265x147 mm | 9.65x10.43x5.79 in 
             | 
        |
| 
             Connectors 
             | 
            
             2x ANT, 2x BTS, AISG Female 8 pin circular 
             | 
        |
| 
             RF Connectors type 
             | 
            
             4.3-10(f) 
             | 
        |
| 
             Mounting (Supporter Pole Diameter: 40-140mm) 
             | 
            
             Hose clamps, arbitrary orientation 
             | 
        |
| 
             Volume 
             | 
            
             9.5 l 
             | 
            
             | 
        
| 
             Weight gross/net 
             | 
            
             12.7 kg / 11.80 kg | 28.0 lb / 26.01 lb 
             | 
        |
| 
             Colour 
             | 
            
             NCS 1502-R 
             | 
        |
| 
             Bracket 
             | 
            
             Included 
             | 
        |
 
.jpg)